10 Kw Solax Inverter Solos Station Rosen Storage Hybrid Solar Power System for Street

10 Kw Solax Inverter Solos Station Rosen Storage Hybrid Solar Power System for Street

10 Kw Solax Inverter Solos Station Rosen Storage Hybrid Solar Power System for Street

10 Kw Solax Inverter Solos Station Rosen Storage Hybrid Solar Power System for Street

The wind capacity of such mounting system can reach (40m/s, 32.5kg/ square meters, level 13), snow load capacity can rea

Details
Basic Info.
Model NO. SMSH-10KW
System Mounting Flat Roof
Working Temperature(ºC): -30 - +60
Charge Method Utility Grid or Solar Panel
Roof Required Areas: 8-10 Sq.Meters Per 1kw
Working Time: 6-8hours
Voltage 80kw
IP Rating IP66
PV Mounting Bracket Flat Ground or Roof, or Pitch Roof
Solar Panel Rack 1 Set
Lamp Power 120W
Average Life >8000h
Transport Package Carten
Specification 10KW
Trademark sunmaster
Origin Zhejiang, China
HS Code 9405409000
Production Capacity 1000PCS/Week
Product Description

10 Kw Solax Inverter Solos Station Rosen Storage Hybrid Solar Power System for Street

Connecting Diagram

10 Kw Solax Inverter Solos Station Rosen Storage Hybrid Solar Power System for Street

Configuration List

10 Kw Solax Inverter Solos Station Rosen Storage Hybrid Solar Power System for Street

ItemCertificationDescriptionQ'tyWarranty
Solar panelTUV / IEC / ECMono or Poly2 pcs20 years
InverterCGC / CQC / VDEOne (MPPT) tracking/ 50/60Hz; 230Vac 1500W/ SM-SH1500W1 set5 years
Distribution box
(Optional)
CELighting Protection. Air switch,Fusegar, knifeswitch,1 set5 years
Mounting systemCESlant roof bracket/ Cement Ground bracket/ Soil ground bracket1set10 years
PV cableTUV/ ULDC port PV1-F 1*4mm²20m10 years
AC port YJV-3*6mm²10m10 years

10 Kw Solax Inverter Solos Station Rosen Storage Hybrid Solar Power System for Street


Solar Panel

10 Kw Solax Inverter Solos Station Rosen Storage Hybrid Solar Power System for Street

TypeMONOPOLY
Power class280W335W270W320W
Open Circuit Voltage (Voc)43444343.8
Short Circuit Voltage (Isc)8.359.928.239.42
Max power Voltage (Vmp)36363636.5
Max Power Current (Imp)7.789.37.358.76
Efficiency≥17.1%≥17.2%≥16.5%≥16.4%
Dimension (mm)1650x991x351960x991x351650x991x351960x991x35
Weight (kg)18±5%22.5±5%18±5%22.5±5%
Solar Inverter
Ambient temperature range-25~+60ºC(>45ºC deloading)
Relative humidity0~95%
Max operating altitude4000m (>3000m derating)
Protection degreeIP65
TopologyTransformerless
Night power consumption (W)<1
Cooiong methodNatural convection
Noise emision (dB)<25
DisplayLCD
Warranty (Year)5/10/15/20/25 (Optional) Years
Solar Controller
Rated Charge current(A)40A
Rated DC voltage(V)24/48 automatic identification
Solar input Max voltage(V)42/84
BatteryOver charge protective voltage(V)28.6/57.2
BatteryOver charge recover voltage(V)27.4/54.8
BatteryConstant charge voltage(V)27/54
BatteryOver discharge alarm voltage(V)20/40
Environment Humidity and temperature0-90% No condense,55ºC
Protective FunctionsProtection against anti-charge at night,battery over charge, over discharge protection,Joint-reversed of solar modules
Solar Battery

Nominal Voltage12V
Nominal Capacity100Ah(10hr,1.80V/cell,25ºC)
Approximate Weight27.5 kg
Internal Resistance5.5 mΩ(Lead terminal)
TerminalLead wire(4.0mm²×1.8m)
Maximum Charge Current25 A
Ambient Temperature-35~55 ºC
DimensionLength329mm(±2 mm)
Width172mm(±2 mm)
Container Height214mm(±2 mm)
Total Height236mm(±2 mm)
CaseABS
PV Combiner Box
ComponentsParameterFunction
Circuit breaker (Air switch)40AWhen the current of the protected,circuit exceeds the specified value,the circuit breaker will automatically break off to protect the whole circuit.
Fusegear40AWhen the current of the protected circuit exceeds the specified value,fusegear will break off automatically
Surge protective device (SPD)UC:420V lmax:20KA
In: 10KAUp≤1.8KV
Photovoltaic lightning protection device
One phase self dual over voltage protection deviceWorking range 220V,50Hz,
over voltage protection
Uvo=270V±5V
Under voltage protection
Uoe= 170±5V
When the circuit voltage is highet or lower, it will shut down automatically.when the voltage reaches standard level, it will recover automatically.
Knife switch/automatic/ by hand

ConductorTinned Fine Re Copper Strand, according to VDE0295/IEC60228. Class 5
InsulationPolyolefin Copolymer electron-beam coss-linked
Sheath JacketPolyolefin Copolymer electron-beam coss-linked
Nominal VoltageUo/U=600V/1000VAC, 1000V/1800VDC
Test Voltage6500V, 50Hz, 5Min
Temperature Rating-40°C-125°C ,More than 25 Years (TUV)
Fire PerformanceIEC 60332-1
Smoke EmissionIEC61034, EN 50286-2
Low Fire LoadDIN 51 900
CertificationTUV 2PFG 1169/08 2007 PV1--F
Mounging System

The wind capacity of such mounting system can reach (40m/s, 32.5kg/ square meters, level 13), snow load capacity can reach 70kg/ square eters

The whole system has strong safety performance.

Can be customized based on customer's cactual situation

The mounting system can be desingned with best solution based on slope roof, flat ground and soil ground



Send Message